F_ACTIVE_RUN_SPEC. Once a run starts these attributes will not change.
The table contains the following attributes:
HYPER_RUN_NUMBER --- The control systems settings identifier
FILL_NUMBER
NOMINAL_ENERGY
NOMINAL_BETAY
MACHINE_MODE
MACHINE_MODE_NUMBER
CURRENT_BREAKPOINT --- which vector number the database thinks the machine is at.
ACTIVE_MTG --- Master timing generator ID
NO_BUNCHLETS --- Number of bunches per train
NO_BUNCH_TRAINS ---
BUNCH_TRAIN_SPACING --- Distance between bunches in a train (RF wavelengths)
BUNCHLET_A_DISPLACEMENT --- Number of RF wavelengths first bunch in train is displaced from nominal
ACTIVE_A --- Do we have the first bunch in the train Y = yes
ACTIVE_B --- Do we have the second bunch in the train