Run Description

The basic stuff which describes the makeup of a run is contain in one table:

F_ACTIVE_RUN_SPEC. Once a run starts these attributes will not change.

The table contains the following attributes:

HYPER_RUN_NUMBER --- The control systems settings identifier

FILL_NUMBER

NOMINAL_ENERGY

NOMINAL_BETAY

MACHINE_MODE

MACHINE_MODE_NUMBER

CURRENT_BREAKPOINT --- which vector number the database thinks the machine is at.

ACTIVE_MTG --- Master timing generator ID

NO_BUNCHLETS --- Number of bunches per train

NO_BUNCH_TRAINS ---

BUNCH_TRAIN_SPACING --- Distance between bunches in a train (RF wavelengths)

BUNCHLET_A_DISPLACEMENT --- Number of RF wavelengths first bunch in train is displaced from nominal

ACTIVE_A --- Do we have the first bunch in the train Y = yes

ACTIVE_B --- Do we have the second bunch in the train